Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 24 jul 2007 to 10 aug 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

The test item didn't burn. It melts in contact of the ignition source. No further testing was required.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
Vanilline is not "highly flammable" under the conditions of the test.
Executive summary:

In a study to determine the flammability of Vanilline, the test Flammability according to the EC A10 guideline was performed (CRTL, 2008).

The test item didn't burn. It melts in contact of the ignition source, and no further testing was required.

Vanilline is not "highly flammable" under the conditions of the test, and according to the EC criteria.

Endpoint:
flammable solids
Data waiving:
other justification
Justification for data waiving:
other:

Description of key information

The test item didn't burn. It melts in contact of the ignition source, and no further testing was required.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

It was performed according to the EC A10 guideline and GLP.

Experience in handling and use of the substance provide sufficient information to indicate that it is neither flammable on contact with water nor pyrophoric.

Justification for classification or non-classification