Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 204-428-0 | CAS number: 120-82-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: Comparable to guideline study with acceptable restrictions
Data source
Referenceopen allclose all
- Reference Type:
- publication
- Title:
- Ûberprüfung der durchführbarkeit von Prüfungsvorschriften und der Aussagekraft der Grundprüfung des E. Chem. G
- Author:
- Korte F and Greim H
- Year:
- 1 981
- Bibliographic source:
- Umweltforschungsplan des Umweltministeriums des Innern, Chemikalien, Forschungsbericht 107 04 006/01. 172
- Reference Type:
- secondary source
- Title:
- European Union Risk Assessment Report - 1,2,4-Trichlorobenzene
- Author:
- European Commission - European Chemicals Bureau
- Year:
- 2 003
- Bibliographic source:
- Office for Official Publications of the European Communities
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 405 (Acute Eye Irritation / Corrosion)
- Deviations:
- yes
- Remarks:
- No GLP. Results were not reported in detail. Not all mandatory timepoints are given.
- GLP compliance:
- no
- Remarks:
- GLP was not mandatory at the time of the study
Test material
- Reference substance name:
- 1,2,4-trichlorobenzene
- EC Number:
- 204-428-0
- EC Name:
- 1,2,4-trichlorobenzene
- Cas Number:
- 120-82-1
- Molecular formula:
- C6H3Cl3
- IUPAC Name:
- 1,2,4-trichlorobenzene
- Details on test material:
- - Name of test material (as cited in study report): 1,2,4-trichlorobenzene
- Analytical purity: 98%
Constituent 1
Test animals / tissue source
- Species:
- rabbit
- Strain:
- other: white Russian
- Details on test animals or tissues and environmental conditions:
- TEST ANIMALS
- Weight at study initiation: 2.5-2.8 kg
- Housing: animals were individually housed in V2A-Steel cages (floor area 0.4 m²)
- Diet (e.g. ad libitum): ad libitum
- Water (e.g. ad libitum): ad libitum
ENVIRONMENTAL CONDITIONS
- Temperature (°C): 20 ± 3°C
- Humidity (%): 60%± 5%
- Photoperiod (hrs dark / hrs light): 12 hrs dark / 12 hrs light
Test system
- Vehicle:
- other: no data. The right eye was used as control and was treated with 0.1 mL NaCl isotonic solution
- Controls:
- other: the right eye was used as control
- Amount / concentration applied:
- TEST MATERIAL
- Concentration (if solution): 100 mg/ 0.1 mL - Duration of treatment / exposure:
- 24 hours
- Observation period (in vivo):
- until 72 hours
- Number of animals or in vitro replicates:
- 6
- Details on study design:
- Prior to the application and 1, 24, and 72 hours after application, the eyes were ophthalmologic investigated. The eye response was reviewed by 2 independent investigators. In the event of discrepancies in the assessment was the mean value was calculated.
24 hours after application the eye was also treated with fluorescein (Fluorescein Sodium eye solution USP) and then investigated.
The evaluation of the eye response was similar to the Draize scheme:
1) CORNEA Assessment
Opacity
No Opacity 0
Scattered or diffuse 1*
opacities, iris still
clearly visible
Not entirely transparent areas, 2*
details of iris indistinct
Opalescent area, details of 3*
iris not visible,
Size of the pupil difficult to
determine
Opaque, invisible iris 4*
2) IRIS
Normal 0
Abnormal wrinkle formation,
congestion, 1*
swelling, vascular injection,
iris still reacts to light
No reaction to light, haemorrhage, 2*
severe destruction
3) CONJUNCTIVA
Erythema
Normal vessels 0
Hyperaemia 1
Diffuse redness, individual 2*
vessels can not be distinguished
massive redness all sections 3*
Swelling: lids and /or nictitating membrane
No swelling
Light swelling
(inclusive of nictitating membrane) 1
Externally visible swelling with 2*
exstrophy of the lids
Swelling that causes half-close lids 3*
Swelling that causes more then half-close 4*
to complete closed lids
The grades marked with * are considered positive reactions evaluated
Results and discussion
In vivo
Results
- Irritation parameter:
- conjunctivae score
- Basis:
- mean
- Remarks:
- 6 animals
- Time point:
- 24/48/72 h
- Score:
- 1
- Max. score:
- 3
- Reversibility:
- not specified
- Irritant / corrosive response data:
- There were no effects on the cornea or iris; test scores for conjunctiva redness and oedema were 1 and 0-2, respectively. 1,2,4-trichlorobenzene resulted in a slight irritation. Fluorescein test was negative.
Any other information on results incl. tables
Detailed test results are not available
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Executive summary:
Korte & Greim (1981)
The irritation/ corrosion potential of 1,2,4-trichlorobenzene was investigated with acute irritation/corrosion according to OECD 405 with deviations 1,2,4-TCB (No GLP. Results were not reported in detail), resulted in a slight irritation. There were no effects on the cornea or iris; test scores for conjunctiva redness and oedema were 1 and 0-2, respectively. Detailed test results are not available. 1,2,4-TCB was found to be non-irritating to the eye according to the GHS criteria.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.