Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 June to 29 October 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Test item code: 2013-001545
Batch / Lot number: 92138436
Content of Captan (stated): 94 %
Appearance / Colour: Solid Powder, off-white
Certificate of analysis: 04 April 2013
Expiry date: 20 July 2014
Storage conditions: Ambient temperature under dark and dry conditions.
Supplier: Makhteshim Chemical Works Ltd.
Contact with:
powdered cellulose
Key result
Sample tested:
test mixture as specified
Remarks:
Mixture of Test substance/cellulose: 3/7 (w/w), Table 5
Parameter:
burning rate
Result:
0.096 mm/s
Remarks on result:
other: mixture does not ignite
Key result
Sample tested:
test mixture as specified
Remarks:
Mixture of Test item/cellulose: 3/7 (w/w); Oxidizer concentration: 70 %, Table 2
Parameter:
burning rate
Result:
0.081 mm/s
Remarks on result:
other: mixture does not ignite
Sample tested:
reference mixture as specified
Remarks:
Mixtures of barium nitrate/cellulose: 6/4 (w/w), Table 1
Parameter:
burning rate
Result:
>= 0.784 - <= 0.837 mm/s

Table 1: Burning rates of barium nitrate/cellulose-standard mixtures




























































Mixture


of


barium nitrate/


cellulose


(w/w)



Burning time after


the reaction zone


propagated an initial


distance of 30 mm


[s]



Covered distance after


the reaction zone


propagated an initial


distance of 30 mm


[mm]



Burning


rate


[mm/s]



6/4



250



200



0.800



6/4



239



200



0.837



6/4



247



200



0.810



6/4



248



200



0.806



6/4



255



200



0.784



6/4



249



200



0.803



Mean [mm/s]:



0.081



Std.Dev. [mm/s]:



0.473



Std.Dev. %:



0.651



RSD = relative standard deviation


 


Table 2: Burning rates of of test item/cellulose-mixtures containing 10 to 90 % of test item












































































Mixture


of


Test item/


cellulose


(w/w)



Oxidizer


concentration


[%]



Burning time after


the reaction zone


propagated an initial


distance of 30 mm


[s]



Covered distance after


the reaction zone


propagated an initial


distance of 30 mm


[mm]



Burning


rate


[mm/s]



9/1



10



0



0



-



8/2



20



0



0



-



7/3



30



0



0



-



6/4



40



0



0



-



5/5



50



0



0



-



4/6



60



0



0



-



3/7



70



185



15



0.081



2/8



80



423



200



0.473



1/9



90



307



200



0.651



 


Table 5: Burning rates of test item/cellulose-mixtures with 30 % test item




























































Mixture


of


Test substance/


cellulose


(w/w)



Burning time after


the reaction zone


propagated an initial


distance of 30 mm


[s]



Covered distance after


the reaction zone


propagated an initial


distance of 30 mm


[mm]



Burning


rate


[mm/s]



3/7



185



15



0.081



3/7



190



20



0.105



3/7



180



21



0.117



3/7



192



25



0.130



3/7



191



17



0.089



3/7



186



10



0.054



Mean [mm/s]:



0.096



Std.Dev. [mm/s]:



0.03



Std.Dev. %:



28.48



RSD = relative standard deviation

Interpretation of results:
GHS criteria not met
Conclusions:
Captan Technical is not considered to be an oxidizing substance because the maximum burning rate ofthe test item/cellulose-mixture was lower than the burning rate ofthe reference mixture.
Executive summary:

The aim of this study was the determination ofthe oxidizing properties (solids)
of the test item. The test was performed following EEC directive A.17. In accordance with the provisions of regulation 1272/2008, Annex I, 2.14, it is proposed classification is not required.

Description of key information

The aim of this study was the determination ofthe oxidizing properties (solids)
of the test item. The test was performed following EEC directive A.17. In accordance with the provisions of regulation 1272/2008, Annex I, 2.14, it is proposed classification is not required.

Key value for chemical safety assessment

Additional information

Due to chemical structure captan is not expected to have oxidising properties. All chlorine and oxygen atoms are bond to carbon.

Justification for classification or non-classification