Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Justification for type of information:
Comparable to guideline study with acceptable restrictions
Qualifier:
no guideline followed
Principles of method if other than guideline:
Particle size distribution was determined using a sieve shaker. A set of 4 sieves were used (pore size 500, 300, 212 and 125 µm)
GLP compliance:
no
Type of method:
sieving
Type of distribution:
counted distribution
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
No.:
#1
Size:
> 500 µm
Distribution:
1.5 %
No.:
#2
Size:
300 - 500 µm
Distribution:
7.7 %
No.:
#3
Size:
212 - 300 µm
Distribution:
14.9 %
No.:
#4
Size:
125 - 212 µm
Distribution:
39.8 %
No.:
#5
Size:
< 125 µm
Distribution:
36.1 %
Conclusions:
The particle size distribution of the Sodium dodecylbenzenesulfonate was determined in a non-GLP study (2012) by using the dry sieve test.
Results:
<125µm: 36.1%
125-212µm: 39.8%
212-300µm: 14.9%
300-500µm: 7.7%
>500µm: 1.5%
Executive summary:

The particle size distribution of the Sodium dodecylbenzenesulfonate was determined in a non-GLP study (2012) by using the dry sieve test.

Results:

Particle size µm 

 %

 > 500

 1.5

 300 - 500

 7.7

 212 - 300

 14.9

 125 - 212

 39.8

 < 125

 36.1

 

Description of key information

The particle size distribution of the Sodium dodecylbenzenesulfonate  was determined in a non-GLP study (2012) by using the dry sieve test.
Results:
Particle size µm %
> 500 1.5
300 - 500 7.7
212 - 300 14.9
125 - 212 39.8
< 125 36.1

Additional information

The particle size distribution of the Sodium dodecylbenzenesulfonate was determined in a non-GLP study (2012) by using the dry sieve test.

Results:

Particle size µm 

 %

 > 500

 1.5

 300 - 500

 7.7

 212 - 300

 14.9

 125 - 212

 39.8

 < 125

 36.1