Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187
Deviations:
no
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution

Test material

1
Chemical structure
Reference substance name:
8-chloro-6-(trifluoromethyl)imidazo[1,2-a]pyridine-2-carboxylic acid
Cas Number:
353258-35-2
Molecular formula:
C9H4ClF3N2O2
IUPAC Name:
8-chloro-6-(trifluoromethyl)imidazo[1,2-a]pyridine-2-carboxylic acid
Specific details on test material used for the study:
Test substance: IN-QEK31-011
Batch No.: SG0312574
Purity: 98.2%

Results and discussion

Particle sizeopen allclose all
Key result
Percentile:
other: L10 D (v, 0.1)
Mean:
1.45 µm
Key result
Percentile:
other: L50 D (v, 0.5)
Mean:
21.4 µm
Key result
Percentile:
other: L90 D (v, 0.9)
Mean:
81.5 µm

Applicant's summary and conclusion

Conclusions:
The L10 D (v, 0.1) was determined to be 1.45 μm, the L50 D (v, 0.5) was determined to be 21.4 μm and the L90 D (v, 0.9) was determined to be 81.5 μm.
Executive summary:

The particle size distribution of the test substance was determined using the laser diffraction method with dry dispersion according to CIPAC MT 187.


The L10 D (v, 0.1) was determined to be 1.45 μm, the L50 D (v, 0.5) was determined to be 21.4 μm and the L90 D (v, 0.9) was determined to be 81.5 μm.