Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7200 (Melting Point / Melting Range)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
yes
Type of method:
other: photocell detection

Test material

1
Chemical structure
Reference substance name:
8-chloro-6-(trifluoromethyl)imidazo[1,2-a]pyridine-2-carboxylic acid
Cas Number:
353258-35-2
Molecular formula:
C9H4ClF3N2O2
IUPAC Name:
8-chloro-6-(trifluoromethyl)imidazo[1,2-a]pyridine-2-carboxylic acid
Specific details on test material used for the study:
Test substance: IN-QEK31-011
Batch No.: SG0312574
Purity: 98.2%

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
199.4 °C

Applicant's summary and conclusion

Conclusions:
Melting point of test substance was 199.4 ± 0.2°C
Executive summary:

This study was conducted according to the guidelines OECD 102, OPPTS 830.7200 and EEC A.1. 


The melting point of test item was determined by photocell detection using a calibrated “Mettler Toledo FP90 thermosystem with FP81 HT measuring cell”. The melting point of test item was determined to be 199.4 ± 0.2°C.