Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Deviations:
no
GLP compliance:
yes

Test material

1
Chemical structure
Reference substance name:
8-chloro-6-(trifluoromethyl)imidazo[1,2-a]pyridine-2-carboxylic acid
Cas Number:
353258-35-2
Molecular formula:
C9H4ClF3N2O2
IUPAC Name:
8-chloro-6-(trifluoromethyl)imidazo[1,2-a]pyridine-2-carboxylic acid
Specific details on test material used for the study:
Test substance: IN-QEK31-011
Batch No.: SG0312574
Purity: 98.2%

Study design

Contact with:
other: cellulose mixture

Results and discussion

Test results (Oxidising solids)
Key result
Sample tested:
test mixture as specified
Remarks:
Test substance/cellulose mixtures are prepared containing 10 to 90% by weight of test substance in 10% increments
Parameter:
maximum burning rate
Result:
0.8 mm/s
Remarks on result:
other: The test substance is not an oxidizing solid

Applicant's summary and conclusion

Conclusions:
The test substance is not an oxidizing solid.
Executive summary:

The test substance was subjected to oxidizing solids testing according to the guideline EC Test A17. The maximum burning rate for the test substance / cellulose mixture was found to be less than the burning rate for the reference mixture.