Registration Dossier

Physical & Chemical properties

Stability in organic solvents and identity of relevant degradation products

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
stability in organic solvents and identity of relevant degradation products
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05.02.2013-13.02.2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Data is from experimental study report
Qualifier:
according to
Guideline:
other: As mentioned below
Principles of method if other than guideline:
Changes in Mass Spectra after dissolving in solvents
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Test substance stable:
yes
Transformation products:
no
Conclusions:
Test chemical was found to be stable in organic solvent dichloro methane and no degradation products were formed after 24 hours as evident from the GC-MS chromatogram obtained at 0 hours and that obtained after 24 hours.
Executive summary:

Test chemical was found to be stable in organic solvent dichloro methane and no degradation products were formed after 24 hours as evident from the GC-MS chromatogram obtained at 0 hours and that obtained after 24 hours.

Description of key information

4,4'-methylenedi-2,6-xylenol was found to be stable in organic solvent dichloro methane and no degradation products were formed after 24 hours as evident from the GC-MS chromatogram obtained at 0 hours and that obtained after 24 hours.

Additional information

4,4'-methylenedi-2,6-xylenol was found to be stable in organic solvent dichloro methane and no degradation products were formed after 24 hours as evident from the GC-MS chromatogram obtained at 0 hours and that obtained after 24 hours.