Registration Dossier

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
25 Jun 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: ASTM E537-07
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Boiling pt.:
>= 279.8 - <= 305.7 °C
Atm. press.:
100.9 kPa
Conclusions:
The boiling point was between 279.8 and 305.7 ˚C at 100.9 kPa.
Executive summary:

To determine the boiling temperature of the test substance a study was performed according to ASTM E537-07 and in compliance with GLP. This DSC study showed a boiling point between 279.8 and 305.7 ˚C at 100.9 kPa.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
25 Jan 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: ASTM E537-07
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Boiling pt.:
>= 240.4 - <= 313.3 °C
Atm. press.:
102.9 kPa
Conclusions:
The boiling point was observed between 240.4 and 313.3 ˚C at 102.9 kPa.
Executive summary:

To determine the boiling temperature of the test substance a study was performed according to ASTM E537-07 and in compliance with GLP. This DSC study showed a boiling point between 240.4 and 313.3 ˚C at 102.9 kPa.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
25 Jan 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: ASTM E537-07
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Boiling pt.:
>= 239.4 - <= 314.1 °C
Atm. press.:
102.9 kPa
Conclusions:
The boiling point was observed between 239.4 and 314.1 ˚C at 102.9 kPa.
Executive summary:

To determine the boiling temperature of the test substance a study was performed according to ASTM E537-07 and in compliance with GLP. This DSC study showed a boiling point between 239.4 and 314.4 ˚C at 102.9 kPa.

Description of key information

The boiling point of the test subtstance was conducted according to the ASTM E537-07 method by using DSC and was found to be 239.9 - 314.1 ˚C.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
279 °C

Additional information

279 °C is the median range of the experimental values.