Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
calculation (if not (Q)SAR)
Remarks:
Migrated phrase: estimated by calculation
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data reported in limited detail but published in a standard reference handbook
Qualifier:
no guideline available
Principles of method if other than guideline:
Extrapolated vapour pressure was calculated at 25°C from an Antoine's or similar equation, which was derived from an experimental data range above or below 25°C.
GLP compliance:
not specified
Temp.:
25 °C
Vapour pressure:
0 mm Hg
Conclusions:
This standard reference reports the vapour pressure of succinic anhydride as 0.00000286 mm Hg.
Executive summary:

The vapour pressure of succinic anhydride was extrapolated from an experimental data range above or below 25°C and reported in The Handbook of Physical Properties of Organic Chemicals as 2.86 x 10-6 mm Hg at 25°C.

Description of key information

The vapour pressure of succinic anhydride is 2.86 x 10-6 mm Hg at 25 °C (0.000381 Pa).

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information

The vapour pressure of succinic anhydride was extrapolated from an experimental data range above or below 25 °C and reported in The Handbook of Physical Properties of Organic Chemicals as 2.86 x 10-6mm Hg at 25 °C (0.000381 Pa).