Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: non-GLP compliant guideline study, available as unpublished report, adequate for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Type of method:
static method

Test material

Constituent 1
Reference substance name:
NOVABIS/NOVAFEED
IUPAC Name:
NOVABIS/NOVAFEED
Details on test material:
Supplier: NOVACARB
Appearance: White cristalline powder
Storage: In darkness at room temperature without humidity
Identification number for the study 08-139

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
66.9 Pa

Any other information on results incl. tables

The vapour pressure of NOVABIS/NOVAFEED at 20 °C is equal to 66.9 Pa.