Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2000.04.04-2000.09.21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study performed in accordance with recognized guideline without deviations.
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Principles of method if other than guideline:
NA
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning time (test type not further specified)
Remarks on result:
other: L-TEE failed to ignite in the test.

NA

Interpretation of results:
not classified based on GHS criteria
Conclusions:
L-TEE was determined non flammable as it failed to ignite in the test.
Executive summary:

The flammability of L-TEE was determined by measuring the burning rate preprared as a pile of set dimensions in accordance with EU Methods A10 (Solids). L-TEE was determined non flammable as it failed to ignite.

Description of key information

L-TEE was determined non flammable as it failed to ignite.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The flammability of L-TEE was determined in accordance with EU Method A.10. L-TEE was determined non flammable as it failed to ignite.

Justification for classification or non-classification

Based on these results, L-TEE is not expected to have hazardous properties and is not classified according to CLP or DSD-DPD for this endpoint.