Administrative data

Link to relevant study record(s)

Reference
Endpoint:
toxicity to microorganisms, other
Remarks:
OECD 301F study performed
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study carried out in compliance with the OECD Principles of Good Laboratory Practice (GLP). The OECD Guideline 301F was followed and there were no deviations to study protocol. Validation criteria were fulfilled.
Qualifier:
according to guideline
Guideline:
other: OECD301F
Deviations:
no
GLP compliance:
yes
Details on sampling:
Aerobic respirometer. Contineuos measurement of oxygen consumption (CO2 production)
Vehicle:
no
Test organisms (species):
activated sludge
Test type:
static
Limit test:
no
Total exposure duration:
28 d
Reference substance (positive control):
yes
Remarks:
Sodium benzoate
Key result
Duration:
28 d
Dose descriptor:
NOEC
Effect conc.:
> 20 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
growth inhibition
Details on results:
No inhibition of the microorganisms was observed during the biodegradation test. Therefore the NOEC is determined to be > 20 mg/L (the concentration applied in the test)
Conclusions:
There was no inhibition of microorganisms at the concentration tested (20 mg/L). Therefore the NOEC is reported as > 20 mg/L
Executive summary:

The Biodegradation of L-TEE was tested applying the OECD Guideline No. 301F. The toxicity control showed no toxicity and is therefore interpretated as a NOEC for microorganisms. The NOEC is therefore reported as > 20 mg/L

Description of key information

No inhibition of the microorganisms  was observed during the biodegradation test. Therefore the NOEC is determined to be > 20 mg/L (the concentration applied in the test)

Key value for chemical safety assessment

EC10 or NOEC for microorganisms:
20 mg/L

Additional information