Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
phototransformation in air
Type of information:
calculation (if not (Q)SAR)
Remarks:
Migrated phrase: estimated by calculation
Adequacy of study:
other information
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: 4e: Documentation insufficient for assessment. Accepted calculation method but not sufficient information in order to challenge the validity of the calculated data.
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Materials and methods

Principles of method if other than guideline:
Programme V.1.89.Syracuse Corp. This method is described in W.M.Meylan and P.H.Howard, Chemosphere, Vol.26, N°12,pp2293-2299, 1993.

Test material

Constituent 1
Chemical structure
Reference substance name:
1,3-diphenylguanidine
EC Number:
203-002-1
EC Name:
1,3-diphenylguanidine
Cas Number:
102-06-7
Molecular formula:
C13H13N3
IUPAC Name:
1,3-diphenylguanidine
Details on test material:
no data
Specific details on test material used for the study:
Details on properties of test surrogate or analogue material (migrated information):
No data.

Study design

Estimation method (if used):
Programme V.1.89.Syracuse Corp. This method is described in W.M.Meylan and P.H.Howard, Chemosphere, Vol.26, N°12,pp2293-2299, 1993.
Details on light source:
Not applicable.
Details on test conditions:
Sensitiser (for indirect photolysis): OH
Sensitiser concentration: 1000000 molecule/cm³
Reference substance:
no

Results and discussion

Preliminary study:
Not applicable.
Test performance:
Not applicable.
Results with reference substance:
Not applicable.

Any other information on results incl. tables

Rate constant (for indirect photolysis): = 0.000000000085 cm³/(molecule*sec) Degradation in % (for indirect photolysis): = 50 after 2.3 hour(s)

Applicant's summary and conclusion

Validity criteria fulfilled:
not applicable
Remarks:
estimation method
Conclusions:
Rate constant (for indirect photolysis): = 0.000000000085 cm³/(molecule*sec) Degradation in % (for indirect photolysis): = 50 after 2.3 hour(s)
Executive summary:

Phototransformation of DPG (1,3 -diphenylguanidine) was estimated with Programme V.1.89. Syracuse Corp. This method is described in W.M.Meylan and P.H.Howard, Chemosphere, Vol.26, N°12,pp2293-2299, 1993.

Rate constant (for indirect photolysis): = 0.000000000085 cm³/(molecule*sec)

Degradation in % (for indirect photolysis): = 50 after 2.3 hour(s).

Nevertheless, not enough information is given in order to challenge the validity of this estimation.