Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 AUG 2009 to 11 JAN 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test O.1 (Test for oxidizing solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Contact with:
other: potassium bromate and cellulose
Sample tested:
4:1 sample-to-cellulose ratio
Parameter:
burning rate
Remarks on result:
mixture does not ignite and burn
Sample tested:
1:1 sample-to-cellulose ratio
Parameter:
burning rate
Result:
376 s
   Mixture 4:1 (Substance : Cellulose) [s]  Mixture 1:1 (Substance : Cellulose) [s]
 Run 1

the amount was not ignitable

 489

 Run 2

 372

 Run 3

 362

 Run 4

 327

 Run 5

 330

 Mean

 

 376

Comparison of the burning times of the substance/cellulose and potassium bromate/cellulose

   Burning time  Last reference measurement: 2008 -03 -07
Mixture (Substance : Cellulose)  greater than  equals  less than  Mixture (Potassium bromate : cellulose)  Burning time [s]
 4:1 or 1:1  x      3:2  20
 4:1 or 1:1  x      2:3  52
 4:1 or 1:1  x      3:7  133
 4:1 an 1:1  x      3:7  133

The sample has no oxidizing properties when tested according to UN Test O.1.

Interpretation of results:
other: EU GHS criteria not met
Conclusions:
The test substance has no oxidising properties when tested according to UN Test O.1.
Executive summary:

The oxidising properties of the substance was assessed durign a GLP-study according to UN Test O.1. The test item has a burning time greater than the reference and has therefore no oxidising properties.

Description of key information

The oxidising properties of the substance was assessed durign a GLP-study according to UN Test O.1. The test item has a burning time greater than the reference and has therefore no oxidising properties.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification

The test item has a burning time greater than the reference and has therefore no oxidising properties.