particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-06-22
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
ISO 13320:2009 “Particle size analysis – Laser diffraction methods”
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
2009
GLP compliance:
not specified
Type of method:
Laser scattering/diffraction
Remarks:
Water as dispersion liquid
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
0.69 µm
Remarks on result:
other: applying Fraunhofer approximation, Urel +/- 14%
Percentile:
D50
Mean:
1.8 µm
Remarks on result:
other: applying Fraunhofer approximation, Urel +/- 4%
Percentile:
D90
Mean:
3.37 µm
Remarks on result:
other: applying Fraunhofer approximation, Urel +/- 8%

Mean diameters (distribution type: number) are for the same sample: D90 = 0.90 μm ± 8 % (Urel), D50 = 0.35 μm ± 4 % (Urel), D10 = 0.21μm ± 14% (Urel).

Conclusions:
The following mean diameters (distribution type: volume) could be determined by laser diffraction analysis: D90 = 3.37 μm ± 8 % (Urel), D50 = 1.80 μm ± 4 % (Urel), D10= 0.69 μm ± 14 % (Urel).
Executive summary:

A guideline study according to ISO 13320:2009 (Particle size analysis - Laser diffraction methods) was conducted for determination of the particle size distribution of the test substance titanium nitride in water as dispersion medium. The following particle size distribution could be determined by laser diffraction analysis: D90 = 3.37 μm ± 8 % (Urel), D50 = 1.80 μm ± 4 % (Urel), D10= 0.69 μm ± 14 % (Urel).

Description of key information

The following mean volume diameters were determined for titanium nitride:
D90 = 3.37 μm ± 8 % (Urel), D50 = 1.80 μm ± 4 % (Urel), D10= 0.69 μm ± 14 % (Urel).

Additional information

The laser diffraction test using water as dispersion liquid, performed in accordance to ISO 13320:2009 produced the following mean diameters of titanium nitride (distribution type: volume) by applying Fraunhofer approximation:


Thieleke_2021: D90 = 3.37 μm ± 8 % (Urel), D50 = 1.80 μm ± 4 % (Urel), D10= 0.69 μm ± 14 % (Urel).


In another study report similar values were determined:


Behm_2014: D90 = 3.5 μm, D50 = 1.95 μm, D10 = 0.24 μm.