Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
June 2005
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Remarks:
Certificate of Analysis - Basic data given
Qualifier:
according to guideline
Guideline:
ISO No., other: UIL1024
GLP compliance:
no
Type of method:
open cup
Remarks:
internal method
Key result
Flash point:
250 °C
Atm. press.:
ca. 1 013 hPa

No information given on pressure but assumed to be measured at normal pressure.

Interpretation of results:
GHS criteria not met
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 Oct 2014 - 13 Jan 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
GLP Guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D93
GLP compliance:
yes (incl. QA statement)
Remarks:
The Department of Health of the Government of the United Kingdom
Type of method:
non-equilibrium method closed cup
Remarks:
Pensky-Martens closed cup apparatus
Key result
Flash point:
> 228 °C
Atm. press.:
>= 1 011 - <= 1 018 hPa
Remarks on result:
other: no flash up to boiling of substance

The test method measures the response of a sample to heat and flame under controlled laboratory conditions.

Results:

Closed Cup Flash Point Temperature: No Flash to Boiling

Full test results:

Temperature (°C)

Barometric Pressure (kPa)

Ignition?

Yes (y) / No (n)

Halo/Enlarged test flame?

Yes (y) / No (n)

25 – 159

101.1

n

n

160 – 228

101.1

n

y

Fresh sample

25 – 159

101.8

n

n

160 – 228*

101.8

n

y

* = Due to the sample boiling higher test temperatures could not be attained and therefore testing was terminated

Comment: No flash observed the sample started boiling at approximately 210 °C, producing grey vapours which extinguished the test flame. Testing was terminated at 228 °C.

Interpretation of results:
GHS criteria not met

Description of key information

The flash point of the test substance was determined to be >228 °C at 1011-1018 hPa (EU A.9, closed cup).

Key value for chemical safety assessment

Additional information

The flash point of the test substance was determined in a Pensky-Martens closed cup apparatus. No flash point could be determined due to sample boiling / decomposition at 228 °C under test conditions.

Supporting information measured with an open cup method (205 °C) confirmed a flash point >200 °C.