Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because decomposition occurred during the melting point study

Description of key information

In the melting point study with FAT 40045/Z, no melting point was detected till 350 °C. The test substance started decomposing at 280 °C. Hence the study is considered as technically not feasible.

Key value for chemical safety assessment

Additional information