Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-11-09 to 2010-02-26
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to OECD 114 test guideline, and in compliance with GLP.
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
111
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
44.1

Results

The viscosity is shown in the table 1:

Table 1: DTO Viscosity

Temperature (°C)

Time (s)

Viscosity (mm2/s)

Mean Viscosity

(mm2/s)

20.0 ± 0.5

20.0 ± 0.5

344

349

110

112

111

40.0 ± 0.5

40.0 ± 0.5

507

509

44.0

44.2

44.1

Conclusions:
A viscosity values of 111 (mm2/s) at 20.0 ± 0.5 and 44.1 (mm2/s) at 40.0 ± 0.5 were determined in a reliable study conducted according to OECD 114, and in compliance with GLP.

Description of key information

Viscosity: 111 mm2/s at 20°C (static), 44.1 mm2/s at 40°C (static) OECD 114.

Key value for chemical safety assessment

Viscosity:
111 mm²/s (static)
at the temperature of:
20 °C

Additional information

The viscosity of Distilled Tall Oil has been determined in a reliable study as 111 mm2/s and 44.1 mm2/s at 20°C and 40°C respectively.