Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-07-12 - 2021-07-13
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Key result
Percentile:
D90
Mean:
16.12 µm
Remarks on result:
other: St. dev. not available
Key result
Percentile:
D10
Mean:
3.291 µm
Remarks on result:
other: St. dev. not available
Key result
Percentile:
D50
Mean:
7.804 µm
Remarks on result:
other: St. dev. not available
Conclusions:
The particle size distribution of the test item was determined by laser diffraction (light scattering).

The median particle size D50 of the test item deduced from the particle size distributions was: 7.804 µm.

The median particle size D10 of the test item deduced from the particle size distributions was: 3.291 µm.

The median particle size D90 of the test item deduced from the particle size distributions was: 16.12 µm
Executive summary:

The particle size distribution of the test item was determined by laser diffraction (light scattering).


The median particle size D50 of the test item deduced from the particle size distributions was: 7.804 µm.


The median particle size D10 of the test item deduced from the particle size distributions was: 3.291 µm.


The median particle size D90 of the test item deduced from the particle size distributions was: 16.12 µm.

Description of key information

The particle size distribution of the test item was determined by laser diffraction (light scattering).


The median particle size D50 of the test item deduced from the particle size distributions was: 7.804 µm.


The median particle size D10 of the test item deduced from the particle size distributions was: 3.291 µm.


The median particle size D90 of the test item deduced from the particle size distributions was: 16.12 µm

Additional information