Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1993
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: no data on GLP
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1993
Report date:
1993

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Principles of method if other than guideline:
No data
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
Bis(N,N',N''-trimethyl-1,4,7-triazacyclononane)-trioxo-dimanganese (IV) di(hexafluorophosphate)monohydrate
EC Number:
411-760-1
EC Name:
Bis(N,N',N''-trimethyl-1,4,7-triazacyclononane)-trioxo-dimanganese (IV) di(hexafluorophosphate)monohydrate
Cas Number:
116633-53-5
Molecular formula:
C18 H42 Mn2 N6 O3 . 2 F6 P
IUPAC Name:
dimanganese(4+) bis(1,4,7-trimethyl-1,4,7-triazonane) bis(hexafluoro-λ⁵-phosphanuide) hydrate trioxidandiide
Details on test material:
No data

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

As the substance is a solid, tests A9 and A11 were not conducted. In the A10 Flammability (Solids) test, the initial flame failed to propagate along any of the test piles, and as such the substance was found not to be flammable under the conditions of this test. Tests A12 and A13 were not conducted due to experience in use indicating that negative results would be expected.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Not flammable
Executive summary:

As the substance is a solid, tests A9 and A11 were not conducted. In the A10 Flammability (Solids) test, the initial flame failed to propagate along any of the test piles, and as such the substance was found not to be flammable under the conditions of this test. Tests A12 and A13 were not conducted due to experience in use indicating that negative results would be expected.