Administrative data

Endpoint:
thermal stability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22 Mar 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Remarks:
A2LA (American Association for Laboratory Accreditation)

Test material

Constituent 1
Chemical structure
Reference substance name:
Hydrogen tetrakis[2,2-bis[(allyloxy)methyl]butan-1-olato-O1]bis(ditridecyl phosphito -O'')titanate(2-)
EC Number:
264-709-9
EC Name:
Hydrogen tetrakis[2,2-bis[(allyloxy)methyl]butan-1-olato-O1]bis(ditridecyl phosphito -O'')titanate(2-)
Cas Number:
64157-14-8
Molecular formula:
not applicable (UVCB substance)
IUPAC Name:
dihydrogen 2-{[(di{[bis(tridecyloxy)phosphanyl]oxido}tris({2,2-bis[(prop-2-en-1-yloxy)methyl]butyl}oxido)titaniotetrakis(ylium))oxido]methyl}-1-(prop-2-en-1-yloxy)-2-[(prop-2-en-1-yloxy)methyl]butane

Results and discussion

For thermal stability study

Test substance thermally stable:
no
Operating temperature
Operating temp.:
>= 25 - <= 400 °C

Any other information on results incl. tables

The sample exhibited two exothermal events with average onsets of 469.56 K (196.4 °C) and 623.76 K (350.6 °C). A small endothermic event or possible Tg was observed below 150 °C. To be conservative, the onset of the first exotherm is defined as the start of deviation from the baseline. The extrapolated onset on the exotherm is at a higher temperature of 538.73 K (265.6 °C) average. The average heat of the first exotherm is 152.4 J/g and does not completely return to baseline prior to the start of the second exotherm. The average heat of the second exotherm is 204.9 J/g. The results are summarized in the following table.

 

Replicate #

Exotherm, Onset, K

Peak of Exotherm, K

Heat of Exotherm, J/g

1

470.58 (197.4 °C),
623.83 (350.7 °C)

594.54 (321.4 °C),
631.64 (358.5 °C)

161.0,
208.5

2

468.54 (195.4 °C),
623.69 (350.5 °C)

597.20 (324.1 °C),
631.83 (358.8 °C)

143.7,
201.2

Average

469.56 (196.4 °C),
623.76 (350.6 °C)

595.87 (322.8 °C),
631.74 (358.7 °C)

152.4,
204.9

 