Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other: ASTM D1298
Version / remarks:
No version of the applied ASTM D1298 is reported. All versions refer to the measurements of relative density by means of the Hydrometer Method. Both this method and ASTM D1298 are included in the OECD Guideline 109.
GLP compliance:
no
Type of method:
buoyancy method - hydrometer
Dynamic viscosity of test material:
0.03 Pa*s at 25 °C
Type:
relative density
Density:
0.965 other: dimensionless
Temp.:
25 °C
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other: ASTM D1824 (Standard Test Method for Apparent Viscosity of Plastisols and Organosols at Low Shear Rates)
Version / remarks:
1983
Qualifier:
according to guideline
Guideline:
other: ASTM D2393 (Test Method for Viscosity of Epoxy Resins and Related Components)
Version / remarks:
1980
GLP compliance:
no
Type of method:
other: method not reported
Temp.:
other: 25 °C
Parameter:
dynamic viscosity (in mPa s)
Value:
30

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ASTM D56 (Standard test method for flash point by tag closed cup tester)
GLP compliance:
no
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Tag apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Hydrogen tetrakis[2,2-bis[(allyloxy)methyl]butan-1-olato-O1]bis(ditridecyl phosphito -O'')titanate(2-)
EC Number:
264-709-9
EC Name:
Hydrogen tetrakis[2,2-bis[(allyloxy)methyl]butan-1-olato-O1]bis(ditridecyl phosphito -O'')titanate(2-)
Cas Number:
64157-14-8
Molecular formula:
not applicable (UVCB substance)
IUPAC Name:
dihydrogen 2-{[(di{[bis(tridecyloxy)phosphanyl]oxido}tris({2,2-bis[(prop-2-en-1-yloxy)methyl]butyl}oxido)titaniotetrakis(ylium))oxido]methyl}-1-(prop-2-en-1-yloxy)-2-[(prop-2-en-1-yloxy)methyl]butane

Results and discussion

Flash pointopen allclose all
Flash point:
210 °F
Atm. press.:
ca. 1 013 hPa
Flash point:
98.89 °C
Atm. press.:
ca. 1 013 hPa

Applicant's summary and conclusion