Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 264-709-9 | CAS number: 64157-14-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 15 Mar 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 018
- Report date:
- 2018
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- Deviations:
- no
- GLP compliance:
- yes
Test material
- Reference substance name:
- Hydrogen tetrakis[2,2-bis[(allyloxy)methyl]butan-1-olato-O1]bis(ditridecyl phosphito -O'')titanate(2-)
- EC Number:
- 264-709-9
- EC Name:
- Hydrogen tetrakis[2,2-bis[(allyloxy)methyl]butan-1-olato-O1]bis(ditridecyl phosphito -O'')titanate(2-)
- Cas Number:
- 64157-14-8
- Molecular formula:
- not applicable (UVCB substance)
- IUPAC Name:
- dihydrogen 2-{[(di{[bis(tridecyloxy)phosphanyl]oxido}tris({2,2-bis[(prop-2-en-1-yloxy)methyl]butyl}oxido)titaniotetrakis(ylium))oxido]methyl}-1-(prop-2-en-1-yloxy)-2-[(prop-2-en-1-yloxy)methyl]butane
Constituent 1
- Specific details on test material used for the study:
- STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature and humidity
Test animals / tissue source
- Species:
- cattle
- Strain:
- not specified
- Details on test animals or tissues and environmental conditions:
- SOURCE OF COLLECTED EYES
- Source: Abattoir
- Characteristics of donor animals: greater than 35 weeks of age
- Storage, temperature and transport conditions of ocular tissue: The isolated eyes were transported in a refrigerated container containing Hank's Balanced Salt Solution (HBSS) with penicillin/streptomycin.
- Time interval prior to initiating testing: The bovine eyes were transported to the testing facility laboratory within 24 h of harvest and the test was performed the same day.
- Indication of any existing defects or lesions in ocular tissue samples: The eyes were examined after receipt from the abattoir. Any cornea with visible evidence of neovascularization, pigmentation, opacity or scratches was discarded.
- Indication of any antibiotics used: Penicillin/streptomycin containing HBSS was used for transport.
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL
- Amount applied: 750 µL
NEGATIVE CONTROL:
- Amount applied: 750 µL
- Lot No. SLBV3954
POSITIVE CONTROL:
- Amount applied: 750 µL
- Concentration: 100%
- Lot No. SHBH4983V - Duration of treatment / exposure:
- 10 ± 1 min at 32 ± 1 °C
- Duration of post- treatment incubation (in vitro):
- 2 h at 32 ± 1 °C
- Number of animals or in vitro replicates:
- triplicates for each treatment and control groups
- Details on study design:
- SELECTION AND PREPARATION OF CORNEAS
Corneas free of visible defects were dissected from the surrounding tissues. A 2-3 mm rim of sclera was left attached to each cornea. The excised corneas were then placed in a container of fresh Hank's Balanced Salt Solution (HBSS). A specifically designed corneal holder was used to mount each cornea.
QUALITY CHECK OF THE ISOLATED CORNEAS
A pre-exposure determination of opacity was made for each cornea by measuring each against the blank supplied by the opacitometer. Fresh MEM was added before taking these baseline opacity readings. Any cornea with a value greater than 7 units was discarded.
TREATMENT METHOD: Closed chamber method
The dissected corneas were mounted in specially designed holders that were separated into anterior and posterior chambers and filled separately. Each cornea was mounted allowing the epithelium of the cornea to project into the anterior chamber. The posterior chamber was filled with MEM solution ensuring contact with the endothelium. The anterior chamber was filled with MEM solution, ensuring contact with the epithelium. The entire holder was incubated at 32 ± 1 °C and allowed to equilibrate for at least one hour, but not longer than two hours. Then the corneas were exposed to the appropriate test or control substances for 10 ± 1 min.
REMOVAL OF TEST SUBSTANCE
After the incubation, either the test item or the control substance was removed from the epithelium of the cornea and anterior chamber of the holder by washing with MEM solution containing phenol red. A final rinse was made with MEM without phenol red.
METHODS FOR MEASURED ENDPOINTS
- Corneal opacity: Corneal opacity was determined by the amount of light transmission through the cornea via an opacitometer (OP-KIT, Electro-Design Corporation, RIOM, France). Opacity measurements were made following the 10-minute exposure and MEM solution refill after the 2 h post-treatment incubation.
- Corneal permeability: The passage of sodium fluorescein dye was measured with the aid of a spectrophotometer (Spectronic 20-D Colorimeter Spectrophotometer Milton/Roy, model: 333175) at 490 nm (OD 490).
SCORING SYSTEM: In Vitro Irritancy Score (IVIS)
DECISION CRITERIA
Test substance with an IVIS > 55 was considered as severe irritant/corrosive and labelled Category 1 according to CLP/EPA/GHS.
Test substance with an IVIS ≤ 3 was regarded as non-irritant and labelled in no category.
Test substance with an IVIS > 3; ≤ 55: no prediction can be made.
Results and discussion
In vitro
Results
- Irritation parameter:
- in vitro irritation score
- Remarks:
- mean value of 3 corneas
- Run / experiment:
- 10 min exposure
- Value:
- 2.06
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- ACCEPTANCE OF RESULTS:
- Acceptance criteria met for positive control: The IVIS value of the positive control did not fall within the acceptance range which was two standard deviations of the current historical mean. Although the IVIS of the positive control was slightly higher, the assay was considered acceptable since the IVIS still demonstrated the anticipated outcome of bovine corneas exposed to 100% ethanol for a 10 min exposure: a moderately irritating, non-corrosive response. Additionally, the IVIS of the negative control group was within the range of the historical mean.
Any other information on results incl. tables
Table 1: Results of the test item on optical density/permeability and opacity
Cornea ID |
Pretest Opacity Score |
10-Minute Opacity Score |
2-Hour Opacity Score |
Corrected Opacity Scores |
OD490 nm |
Corrected Optical Density |
|
10-Minute |
2-Hour |
||||||
13 |
0 |
1 |
1 |
1 |
1 |
0.015 |
-0.002 |
14 |
0 |
1 |
1 |
1 |
1 |
0.016 |
-0.001 |
15 |
1 |
4 |
5 |
3 |
4 |
0.032 |
0.015 |
Corrected Mean Optical Density = |
0.004 |
||||||
2-Hour Corrected Mean Opacity Score = |
2 |
Table 2: Results of the negative control on optical density/permeability and opacity
Cornea ID |
Pretest Opacity Score |
10-Minute Opacity Score |
2-Hour Opacity Score |
Corrected Opacity Scores |
OD490 nm |
|
10-Minute |
2-Hour |
|||||
1 |
0 |
0 |
0 |
0 |
0 |
0.017 |
2 |
0 |
0 |
0 |
0 |
0 |
0.016 |
3 |
0 |
0 |
0 |
0 |
0 |
0.019 |
Mean of Individual Optical Density = |
0.017 |
|||||
2-Hour Corrected Mean Opacity Score = |
0 |
Table 3: Results of the positive control on optical density/permeability and opacity
Cornea ID |
Pretest Opacity Score |
10-Minute Opacity Score |
2-Hour Opacity Score |
Corrected Opacity Scores |
OD490 nm |
Corrected Optical Density |
|
10-Minute |
2-Hour |
||||||
4 |
0 |
37 |
35 |
37 |
35 |
0.512 |
0.495 |
5 |
1 |
39 |
36 |
38 |
35 |
0.985 |
0.968 |
6 |
0 |
42 |
39 |
42 |
39 |
0.88 |
0.863 |
Corrected Mean Optical Density = |
0.775 |
||||||
2-Hour Corrected Mean Opacity Score = |
36.33 |
Table 4: Calculated in vitro irritancy scores
Test Article | Negative Control (MEM) | Positive Control (100% Ethanol) |
2.00 + (15 x 0.004) | 0.00 + (15 x 0.017) | 36.33 + (15 x 0.775) |
2.00 + 0.06 | 0.00 + 0.255 | 36.33 + 11.625 |
IVIS = 2.06 | IVIS = 0.26 | IVIS = 47.96* |
Table 5: Historical control data
Historical Data |
Positive Control |
Negative Control |
Mean IVIS |
27.72 |
0.51 |
Standard Deviation |
5.54 |
0.89 |
n |
61 |
61 |
Applicant's summary and conclusion
- Interpretation of results:
- other: CLP/EU GHS criteria not met, no classification required according to Regulation (EC) 1272/2008.
- Conclusions:
- CLP: not classified
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
