Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 202-288-5 | CAS number: 93-92-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Vapour pressure
Administrative data
Link to relevant study record(s)
- Endpoint:
- vapour pressure
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 1st July 2011 to 6th July 2011
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: A GLP compliant study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 104 (Vapour Pressure Curve)
- Deviations:
- yes
- Remarks:
- A first test had to be repeated as one of the determinations showed a deviation in the analytical concentrations compared to those after 4 h and 8 h, most likely due to a chromatographic incident. Only the results of the second, valid test are reported.
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.4 (Vapour Pressure)
- Deviations:
- yes
- Remarks:
- A first test had to be repeated as one of the determinations showed a deviation in the analytical concentrations compared to those after 4 h and 8 h, most likely due to a chromatographic incident. Only the results of the second, valid test are reported.
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7950 (Vapor Pressure)
- Deviations:
- yes
- Remarks:
- A first test had to be repeated as one of the determinations showed a deviation in the analytical concentrations compared to those after 4 h and 8 h, most likely due to a chromatographic incident. Only the results of the second, valid test are reported.
- Principles of method if other than guideline:
- Guidelines were adapted to the following literature:- Etzweiler et al. (1984) Phys. Chem. 88: 578-583- Neuner-Jehle and Etzweiler (1991) Perfumes: Art, Science and Technology. Müller and Lamparsky, eds. Elsevier Applied Science Publishers, London. pp. 153-212.Sampling from the saturated headspace was performed using quasi-static sampling instead of dynamic sampling.
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- gas saturation method
- Specific details on test material used for the study:
- - Name of test material (as cited in study report): 1-phenylethyl acetate
- Physical state: colourless to pale yellow liquid
- Name of test material (as cited in study report): Gardenol
- Lot/batch No.: VE00123242
- Expiration date of the lot/batch: 14th January 2013 - Temp.:
- 20 °C
- Vapour pressure:
- 5.5 Pa
- Conclusions:
- Under the conditions of the test, the vapour pressure of the test substance was determined to be 5.5 Pa at 20 ºC.
- Executive summary:
In a GLP compliant vapour pressure study conducted in line with standardised guidelines OECD 104, EU Method A.4 and EPA OPPTS 830.7950, the vapour pressure of the test substance was determined using the gas saturation method. The vapour pressure of the substance was determined to be 5.5 Pa at 20 ºC.
Reference
Headspace concentrations of the test substance were found to be 343 µg/L, 397 µg/L and 372 µg /L after 4, 6 and 8 hours of equilibration time at 20 ± 0.1 ºC respectively.
Description of key information
The vapour pressure of 1-phenylethyl acetate was determined to be 5.5 Pa at 20ºC according to a study performed in line with OECD Guideline 104, EU Method A.4 and EPA OPPTS 830.7950.
Key value for chemical safety assessment
- Vapour pressure:
- 5.5 Pa
- at the temperature of:
- 20 °C
Additional information
The key study (Givaudan, 2011d) was conducted in line with GLP and standardised guidelines with a sufficient level of detail to assess the quality of the study. The study was performed to a good standard and was assigned a reliability score of 1 in accordance with Klimisch (1997).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.