Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12th September 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and conducted under GLP conditions.
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7100 (Viscosity)
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
- Name of test material (as cited in study report): 1-phenylethyl acetate
- Physical state: colourless to pale yellow liquid
- Name of test material (as cited in study report): Gardenol
- Lot/batch No.: VE00123242
- Expiration date of the lot/batch: 14th January 2013
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.06
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.92

Table 1: Results

 Determination  Temperature (ºC)  Time (s)  Viscosity (mm2/s)  Mean viscosity (mm2/s)
 1A  20 ± 0.5  615.77  3.065  3.06
 1B    614.03  3.056  
 1C    613.32  3.052  
 2A    613.35  3.053  
 2B    613.37  3.053  
 2C    613.37  3.053  
 1A  40 ± 0.5  387.21  1.927  1.92
 1B    385.74  1.920  
 1C    386.50  1.924  
 2A    385.35  1.918  
 2B    385.32  1.918  
 2C    385.38  1.918  
Conclusions:
Under the conditions of the test, the visocisty of of the test substance was determined to be 3.06 mm²/s at 20 ± 0.5 ºC.
Executive summary:

In a non-GLP compliant viscosity study conducted in line with standardised guidelines OECD 114 and EPA OPPTS 830.7100, the viscosity of the test substance was determined to be 3.06 mm2/s at 20 ± 0.5 ºC.

Description of key information

The viscosity of 1-phenylethyl acetate was determined to be 3.06 mm²/s at 20 ± 0.5 ºC according to a study performed in line with OECD Guideline 114 and EPA OPPTS 830.7100. 

Key value for chemical safety assessment

Viscosity:
3.06 mm²/s (static)
at the temperature of:
20 °C

Additional information

The key study (Givaudan, 2011h) was conducted in line with standardised guidelines but not to GLP with a sufficient level of detail to assess the quality of the study. The study was performed to a sufficient standard and was assigned a reliability score of 2 in accordance with Klimisch (1997).