Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
ca. 26 °C
Atm. press.:
ca. 1 atm
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
Flash point of the test substance was 26°C and was classified as flammable liquid category 3 according to GHS standards.
Executive summary:

Flash point of the test substance was 26°C, according to ASTM D93 method using Pensky Martens Closed Cup Method. The substance was therefore classified as Category 3 according to GHS standard.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion