Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
ca. 26 °C
Atm. press.:
ca. 1 atm
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
Flash point of the test substance was 26°C and was classified as flammable liquid category 3 according to GHS standards.
Executive summary:

Flash point of the test substance was 26°C, according to ASTM D93 method using Pensky Martens Closed Cup Method. The substance was therefore classified as Category 3 according to GHS standard.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion