Administrative data

First-aid measures

General advice: Remove contaminated clothing.

If inhaled: Take the person into the fresh air and keep him warm, let him rest; if there is difficulty in breathing, medical advice is required.

In case of skin contact: In case of skin contact wash affected areas thoroughly with soap and plenty of water. Consult a doctor in the event of a skin reaction.

In case of eye contact: Hold the eyes open and rinse with preferably lukewarm water for a sufficiently long period of time (at least 10 minutes). Contact an ophthalmologist.

If swallowed: DO NOT induce the patient to vomit, medical advice is required.

Fire-fighting measures

Suitable extinguishing media: Carbon dioxide (CO2), Foam, extinguishing powder, in cases of larger fires, water spray should be used.

Unsuitable extinguishing media: High volume water jet

Burning releases carbon monoxide, carbon dioxide, oxides of nitrogen and traces of hydrogen cyanide. In the event of fire and/or explosion do not breathe fumes.

Firemen must wear self-contained breathing apparatus.

Do not allow contaminated extinguishing water to enter the soil, ground-water or surface waters.

Accidental release measures

Personal precautions: Put on protective equipment. Ensure adequate ventilation/exhaust extraction. Keep unauthorized persons away.

Environmental precautions: Do not allow to escape into waterways, wastewater or soil.

Methods for cleaning up: Take up with absorbent for chemicals or, if necessary with dry sand and store in closed containers.

Handling and storage

Handling

When handling observe the usual precautionary measures for chemicals. Avoid contact with the skin and the eyes.

In all workplaces or parts of the plant where high concentrations of aerosols and/or vapors may be generated (e.g. during pressure release, mold venting or when cleaning mixing heads with an air blast), appropriately located exhaust ventilation must be provided in such a way that the WEL is not exceeded. The air should be drawn away from the personnel handling the product The efficiency of the exhaust equipment should be periodically checked.

Precautions should generally be taken against electrostatic charges according to the equipment used and the way the product is handled and packaged.

Storage

Keep container tightly closed and dry.

Storage temperature regarding personal safety: max. 50 °C.

Additional information on the storage conditions required for reasons of quality assurance as well as other specific information can be found in the product information sheet.

VCI storage class (VCI = German Association of the Chemical Industry): 10

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Disposal considerations