Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 23 August to 21 November 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes
Type of method:
other: isothermal thermogravimetric effusion method
Temp.:
20 °C
Vapour pressure:
< 0 Pa
Temp.:
25 °C
Vapour pressure:
< 0 Pa
Conclusions:
The vapour pressure of the test item at 20 deg. C (293K) and 25 deg. C (298K) were <1.3E-08 Pa and <1.7E-08 Pa respectively.

Description of key information

The vapour pressure of the test item at 20 deg. C (293K) and 25 deg. C (298K) is <1.3E-08 Pa and <1.7E-08 Pa respectively (WIL Research, 2012).

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information