Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test O.1 (Test for oxidizing solids)
GLP compliance:
no
Specific details on test material used for the study:
Lot PF 907
Contact with:
powdered cellulose
Duration of test (contact time):
> 300 s
Sample tested:
reference: 3:7 mixture potassium bromate + cellulose
Parameter:
mean burning time
Result:
97.4 s
Key result
Sample tested:
4:1 sample-to-cellulose ratio
Parameter:
mean burning time
Result:
> 300 s
Key result
Sample tested:
1:1 sample-to-cellulose ratio
Parameter:
mean burning time
Result:
> 300 s
Interpretation of results:
GHS criteria not met
Conclusions:
Monoamine oxidase is not classified as an oxidizing solid.

Description of key information

Monoamine oxidase is not classified as an oxidizing solid.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification