Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From July 31, 2019 to December 25, 2019
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Phenomena and results from two independent preliminary screening tests were identical:the sample was not ignited within 2 minutes.

Interpretation of results:
GHS criteria not met
Conclusions:
According to UN Manual of Tests and Criteria: Test N.1, Everzol SR98 was not a highly flammable solid. Therefore, Everzol SR98 was not met GHS criteria.
Executive summary:

This test using the procedures outlined in the ZRICI Study Plan for PCF2019-045-07 and UN Manual of Tests and Criteria: Test N.1. In preliminary screening test, the test result showed that Everzol SR98 was not ignited within 2 minutes. Therefore, Everzol SR98 was not a highly flammable solid.

Description of key information

Everzol SR98 is not classified as flammable solids (UN Manual of Tests and Criteria: Test N.1).

Key value for chemical safety assessment

Flammability:
not classified

Additional information

In preliminary screening test, the test result showed that Everzol SR98 was not ignited within 2 minutes. Therefore, Everzol SR98 was not a highly flammable solid.

Justification for classification or non-classification