Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From July 31, 2019 to December 25, 2019
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Key result
Percentile:
D50
Mean:
49.1 µm
St. dev.:
1.344

Obscuration value: 2.46%

Table 1. Cumulative distribution of the Particle size

Cumulative

Commom symbol

d(0.10)

d(0.50)

d(0.90)

Shown symbl

Dv (10)

Dv (50)

Dv (90)

Particle size

23.4 μm

49.1 μm

94.8 μm

Table 2. Average particle size

 

Symbol

Result

Average particle size in surface area

D [3,2]

41.3μm

Average particle size in volume

D [4,3]

54.8μm

Conclusions:
According to ISO 13320:2009, the cumulative distribution of Everzol SR98 are d(0.10)=23.4μm, d(0.50)=49.1μm and d(0.90)=94.8μm, and the average particle size in surface area and volume of Everzol SR98 are 41.3μm and 54.8μm, separately.
Executive summary:

This test using the procedures outlined in the ZRICI Study Plan for PCF2019-045-09 andISO 13320:2009.The obscuration value is out of 0.5%~6%, conforms to the requirement for testing.The determination result can be considered valid.Cumulative distribution of Everzol SR98 are d(0.10)=23.4μm, d(0.50)=49.1μmand d(0.90)=94.8μm. Average particle size in surface area and volume of Everzol SR98 are 41.3μm and 54.8μm, separately.

Description of key information

The determination result can be considered valid. Cumulative distribution of Everzol SR98 are d(0.10)=23.4μm, d(0.50)=49.1μm and d(0.90)=94.8μm. Average particle size in surface area and volume of Everzol SR98 are 41.3μm and 54.8μm, separately. (ISO 13320:2009).

Additional information

The obscuration value is out of 0.5%~6%, conforms to the requirement for testing. The determination result can be considered valid.