Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-08-28
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Batch No.: B893504
Purity: 99.87%
Key result
Flash point:
> 93 °C
Atm. press.:
100.01 kPa
Remarks on result:
no flash point according to standard method
Interpretation of results:
other: Not flammable liquid
Conclusions:
Based on the results, the flash point of test was higher than 93.0 ℃ at 100.01kPa.
Executive summary:

The flash point of test item was determined with close-cup flash point tester according to EC A.9. Based on the results, the flash point of test was higher than 93.0 °C at 100.01kPa.

Description of key information

The flash point of test item was higher than 93.0 °C at 100.01kPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
93 °C

Additional information

The flash point of test item was determined with close-cup flash point tester according to EC A.9. Based on the results, the flash point of test item was higher than 93.0 °C at 100.01kPa.