Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
non-equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: Dark Brown Liquid
Details on test material:
Identity: Cashew Nutshell Extract, Decarboxylated
Appearance: Dark brown liquid
Storage conditions: Room temperature
Lot number: RM-9359 MIXTURE
Purity: UVCB

Results and discussion

Flash point
Flash point:
294 °C
Remarks on result:
other: The barometric pressure at the time of testing was 999 mbar and, thus, no pressure correction was required. The duplicate determined flash points were 294°C and 296°C, the lower of which will be reported as the flash point for safety assessment purposes.

Applicant's summary and conclusion

Executive summary:

The Flashpoint was determined to be 294˚C using the Pensky-Martens Closed Cup Flash Point apparatus using the non-equilibrium method.