Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
Flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Justification for type of information:
Experimental test result performed using standard methods
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Name of test material: 2,2,2-Trichloroethane-1,1-diol (Chloral hydrate)
- Molecular formula: C2-H3-Cl3-O2
- Molecular weight: 165.4026g/mol
- Smiles notation: C(C(O)O)(Cl)(Cl)Cl
- InChl: RNFNDJAIBTYOQL-UHFFFAOYSA-N
- Substance type: Organic
- Physical state: Solid
Key result
Flash point:
75 °C
Atm. press.:
973.4 hPa

Method Details

Observations

Remarks if, any

Method

Closed cup method using Pensky Martin’s Flash Point Apparatus

 

 

Principle of Flash point test

The flash point of a flammable liquid is the lowest temperature at which there will be enough flammable vapor to ignite when an ignition source is applied.

 

 

Type of method

·    Closed cup

 

 

Flash point apparatus

·    Abel’s flash pt apparatus

·    Pensky – Martin’s flash point apparatus

Pensky – Martin’s flash point apparatus

 

Volume of chemical used

Ml /gm

5 gm

 

Ignition source

Gas lighter/flame

Gas lighter

 

Atmospheric pressure

hPa

973.4 hPa

 

Flash point (RESULT)

°C

75 °C

 

Interpretation of results:
other: not flammable
Conclusions:
The mean experimental flash point of 2,2,2-trichloroethane-1,1-diol (CAS No. 302-17-0) determined by the closed cup method was estimated to be 75°C at 973.4 hPa
Executive summary:

The flash point determination of test substance 2,2,2-trichloroethane-1,1-diol (CAS No. 302-17-0 ) was done. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The mean flashpoint of the test substance was found to be 75°C at 973.4 hPa.

Description of key information

The flash point determination of test substance 2,2,2-trichloroethane-1,1-diol (CAS No. 302-17-0 ) was done. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The mean flashpoint of the test substance was found to be 75°C at 973.4 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
75 °C

Additional information

The flash point determination of test substance 2,2,2-trichloroethane-1,1-diol (CAS No. 302-17-0 ) was done. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The mean flashpoint of the test substance was found to be 75°C at 973.4 hPa.