Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
December 10 - December 11, 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
Version / remarks:
(2009)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
Version / remarks:
(2010)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
Amiloride Compound 7
IUPAC Name:
Amiloride Compound 7
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study report): Amiloride Compound 7
- CAS Number: 1458-18-0
- Description: Tan powder

Test system

Amount / concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 750 µl of 20% (w/w) test substance per cornea.
No correction was made for the purity/composition of the test substance.
A 20% (w/w) suspension of Amiloride Compound 7 was prepared in physiological saline.

NEGATIVE CONTROL
- Amount(s) applied (volume or weight with unit): 750 µl of physiological saline per cornea

POSITIVE CONTROL
Amount(s) applied (volume or weight with unit): 750 µl per cornea
Concentration (if solution): 20% (w/v) Imidazole


Duration of treatment / exposure:
240 minutes (4 hours)
Details on study design:
TEST SITE
- Isolated bovine cornea

REMOVAL OF TEST SUBSTANCE
- Washing (if done): yes
- Time after start of exposure: 240 minutes

SCORING SYSTEM:
- After exposure the cornea is thoroughly rinsed to remove the test substance followed by immediate opacity measurement and permeability evaluation of the cornea.

- The mean opacity and mean permeability values (OD490) were used for each treatment group to calculate an in vitro score:

In vitro irritancy score (IVIS) = mean opacity value + (15 x mean OD490 value).


TOOL USED TO ASSESS SCORE:
- opacitymeter and microplate reader

DATA EVALUATION:
A test substance that induces an IVIS ≥ 55.1 is defined as a corrosive or severe irritant

Results and discussion

In vitro

Results
Irritation parameter:
in vitro irritation score
Remarks:
4 hrs
Run / experiment:
mean
Value:
ca. 1.4
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
Negative control: 0.0; Positive control: 111

Any other information on results incl. tables

The corneas treated with Amiloride Compound 7 showed an opacity value of 1 and permeability values ranging from 0.012 to 0.042. The corneas were clear after the 240 minutes of treatment with Amiloride Compound 7. No pH effect of the test substance was observed on the rinsing medium.

Applicant's summary and conclusion

Interpretation of results:
not irritating
Conclusions:
Amiloride Compound 7 is not irritant or corrosive in the Bovine Corneal Opacity and Permeability test.

Executive summary:

The negative control responses of the opacity and permeability values were less than the upper limits of the laboratory historical range indicating that the negative control did not induce irritancy on the corneas.The mean in vitro irritancy score of the positive control (20% (w/v) Imidazole) was 111 and within the historical positive control data range. It was therefore concluded that the test conditions were adequate and that the test system functioned properly.

Amiloride Compound 7 did not induce ocular irritation through both endpoints, resulting in a mean in vitro irritancy score of 1.4 after 240 minutes of treatment.