Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 February 2013 - 03 May 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: UN ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, Part III Paragraph 33.2.1.4 “ Test N.1: “Test method for readily combustible solids” (2009)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
(2008)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Methyl 3-amino-5,6-dichloropyrazine-2-carboxylate
EC Number:
215-947-7
EC Name:
Methyl 3-amino-5,6-dichloropyrazine-2-carboxylate
Cas Number:
1458-18-0
Molecular formula:
C6H5Cl2N3O2
IUPAC Name:
methyl 3-amino-5,6-dichloropyrazine-2-carboxylate
Test material form:
solid: particulate/powder
Details on test material:
Identification: Amiloride Compound 7
Molecular formula: C6H5Cl2N3O2
Molecular weight: 222.03
CAS Number:1458-18-0
Description: Tan powder
Batch: 206-2
Purity/Composition: 99.7 area%
Test substance storage: In refrigerator (2-8°C) protected from light, desiccated
Stability under storage conditions: Stable
Expiry date: 11 May 2014 (Retest date)

Results and discussion

Any other information on results incl. tables

The flame of the gas burner did ignite the test substance pile. The test substance melted, burned with a blue flame and turned into a black residue. White smoke was observed. After removal of the ignition source, the flame extinguished immediately and no propagation of combustion was observed.

Applicant's summary and conclusion

Interpretation of results:
other: 'not highly flammable' by ignition
Conclusions:
Amiloride Compound 7 was determined to be 'not highly flammable' by ignition in a GLP-compliant study performed in accordance with UN MTC Test N.1 and EC.A10.