Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures

First-aid measures after inhalation : Remove victim to fresh air and allow to rest.

First-aid measures after skin contact : Wash immediately with plenty of water.

First-aid measures after eye contact : Rinse immediately and abundantly with water by prising open the eyelids. Consult a specialist.

First-aid measures after ingestion : Get medical advice/attention.

Most important symptoms and effects, both acute and delayed :

No additional information available

Indication of any immediate medical attention and special treatment needed :

Treat symptomatically.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media : Carbon dioxide (CO2). Dry powder. Foam. Water spray.

Special hazards arising from the substance or mixture

Hazardous decomposition products in case of fire : In case of fire, oxides of carbon and nitrogen may be liberated.

Advice for firefighters:

Protection during firefighting : Do not attempt to take action without suitable protective equipment. Wear self-contained breathing apparatus due to dangerous fumes and gases.

Accidental release measures

Personal precautions, protective equipment and emergency procedures

General measures : Avoid dust production.

For non-emergency personnel

No additional information available

For emergency responders

Protective equipment : Protective gloves (Plastic, impervious). Safety glasses. Appropriate protective clothing. In case of insufficient ventilation, use a breathing mask with filter type P3. For further information refer to section : "Exposure controls/personal protection".

Environmental precautions

Prevent from entering sewers or the immediate environment.

Methods and material for containment and cleaning up

For containment : Mechanically recover the product. Shovel into suitable and closed container for disposal. Avoid dust production. Use non-sparking tools. Dispose of in accordance with relevant local regulations.

Other information : Dispose of waste water in conformity with current regulations.

Handling and storage

Precautions for safe handling :

Precautions for safe handling : Ensure good ventilation of the work station. Otherwise wear personal breathing apparatus. Keep away from open flames, hot surfaces and sources of ignition. Avoid dust formation. Use non-sparking tools.

Hygiene measures : Change contaminated clothing and in any case at the end of work. Handle in accordance with good industrial hygiene and safety practice. Always wash hands after handling the product. Do not eat, drink or smoke when using this product.

Conditions for safe storage, including any incompatibilities:

Technical measures : Electrical equipment, including lighting, must conform to current legislation. Avoid dust production. Use only non-sparking tools.

Storage conditions : Keep container tightly closed. Store in dry, well-ventilated area. - Avoid: Storage exposed to bad weather.

Special rules on packaging : Store in original container.

Packaging materials : Recommendations: Plastic. Glass.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not applicable
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not applicable
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not applicable
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not applicable
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters

No additional information available

Exposure controls

Appropriate engineering controls : Ensure good ventilation of the work station. Extraction to remove dust at its source.

Hand protection : Protective gloves (Plastic, impervious). The protective gloves to be used must comply with the specifications of EC directive 89/686/EEC and the resultant standard EN 374. Breakthrough time : refer to the recommendations of the supplier

Eye protection : Safety glasses. (DIN EN 166)

Skin and body protection : Wear suitable protective clothing

Respiratory protection : In case of insufficient ventilation, use a breathing mask with filter type ABEK

Stability and reactivity

Reactivity

To our knowledge, the product does not present any particular risk, under normal conditions of use.

Disposal considerations

Waste treatment methods :

Authorized disposal. Dispose of in a safe manner, in accordance with local regulations. Recover or destroy according to current local regulations.

Chemical stability

Stable at ambient temperature and under normal conditions of use.