Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
explosiveness, other
Remarks:
sensitiveness to impact and friction; effects of heating and ignition under confinement
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 03/07/2003 to 17/07/2003
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report date:
2003

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Part I: Classification procedures, test methods and criteria relating to explosives of Class 1
Qualifier:
according to guideline
Guideline:
other: AFNOR NF T 70-506
Version / remarks:
UN-MTC, part 1 type 1(b)
Qualifier:
according to guideline
Guideline:
other: AFNOR NF T 70-500
Version / remarks:
UN-MTC, part 1 type 3(a)
Qualifier:
according to guideline
Guideline:
other: AFNOR NF T 70-503
Version / remarks:
UN-MTC, part 1 type 3(b)
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Pyrrolidine, 1-[2-[2-nitro-4-(phenylmethoxy)phenyl]ethenyl]-
Cas Number:
99474-22-3
Molecular formula:
C19H20N2O3
IUPAC Name:
Pyrrolidine, 1-[2-[2-nitro-4-(phenylmethoxy)phenyl]ethenyl]-
Test material form:
solid: particulate/powder
Details on test material:
Rèf: OP 05508666/1
Dry powder
Specific details on test material used for the study:
Rèf: OP 05508666/1
Dry powder

Results and discussion

Results of test series for explosivesopen allclose all
Key result
Test series:
UN Test series 1
Method:
UN Test 1 (b): Koenen test
Parameter:
limiting diameter (mm)
Result:
result is considered "-" (negative)
Remarks on result:
other: limiting diameter < 1 mm ; no fragment observed
Key result
Test series:
UN Test series 1
Method:
UN Test 3 (a) (ii): BAM Fallhammer
Parameter:
limiting impact energy (J)
Result:
result is considered "-" (negative)
Remarks on result:
limiting impact energy > 40 J
Key result
Test series:
UN Test series 1
Method:
UN Test 3 (b) (i): BAM friction apparatus
Parameter:
limiting load (N)
Result:
result is considered "-" (negative)
Remarks on result:
other: 0 positive tests from 30 to 353 N

Any other information on results incl. tables

- UN-MTC part 1 type 1(b): Limiting diameter < 1 mm; no fragment observed

- UN-MTC part 1 type 3(a): No positif test between 30 to 50.1 J.

- UN-MTC part 1 type 3(b): No positif tests between 30 to 353 N.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
- UN-MTC part 1 type 1(b): Limiting diameter < 1 mm; no fragment observed
- UN-MTC part 1 type 3(a): No positif test between 30 to 50.1 J.
- UN-MTC part 1 type 3(b): No positif tests between 30 to 353 N.
Executive summary:

The sensitiveness to impact and friction; effects of heating and ignition under confinement of the test item has been assessed in accordance with the UN-MTC part1. The following results had been obtained:

- UN-MTC part 1 type 1(b): Limiting diameter < 1 mm; no fragment observed

- UN-MTC part 1 type 3(a): No positif test between 30 to 50.1 J.

- UN-MTC part 1 type 3(b): No positif tests between 30 to 353 N.

Considering the negative results, the test item should be considered as not explosive.