Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14/02/2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
1992
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Pyrrolidine, 1-[2-[2-nitro-4-(phenylmethoxy)phenyl]ethenyl]-
Cas Number:
99474-22-3
Molecular formula:
C19H20N2O3
IUPAC Name:
Pyrrolidine, 1-[2-[2-nitro-4-(phenylmethoxy)phenyl]ethenyl]-
Test material form:
solid: particulate/powder
Details on test material:
- Lot/batch No.: 0132014
- Brown/black crystals/powder
- According to the sponsor, the test item was considered to be stable during the test
- Storage: in darkness at room temperature without humidity
Specific details on test material used for the study:
- Lot/batch No.: 0132014
- Brown/black crystals/powder
- According to the sponsor, the test item was considered to be stable during the test
- Storage: in darkness at room temperature without humidity

Results and discussion

Flammable solids
Key result
Test procedure:
other: During the preliminary test, the test item ignited after about 40 secondes of the flame application. Then a combustion with a flame was observed for about 1 minute. The test item melted and formed a blackened crust. There was no flame propagation.
Remarks on result:
other: During the preliminary test, the test item ignited after about 40 secondes of the flame application. Then a combustion with a flame was observed for about 1 minute. The test item melted and formed a blackened crust. There was no flame propagation.

Any other information on results incl. tables

PRELIMINARY TEST:

  • Assay No.1

The test item ignited after about 40 secondes of the flame application. Then a combustion with a flame was observed for about 1 minute. The test item melted and formed a blackened crust. There was no flame propagation.

  • Assay No.2

The test item ignited after about 40 secondes of the flame application. Then a combustion with a flame was observed for about 1 minute. The test item melted and formed a blackened crust. There was no flame propagation.

MAIN-TEST:

Not performed considering the preliminary test results.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item was not considered as highly flammable under the experimental conditions
Executive summary:

The flammability of the test item was studied in GLP-compliant conditions according to the EU method A.10 (1992). During the preliminary test, the test item ignited after about 40 secondes of the flame application. Then a combustion with a flame was observed for about 1 minute. The test item melted and formed a blackened crust. There was no flame propagation. No main test was performed considering the preliminary test results.

The test item was not considered as highly flammable under the experimental conditions.