Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
yes (incl. QA statement)
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
82 °C
Atm. press.:
1 013 hPa

Description of key information

82°C at 1013 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
82 °C

Additional information

The determination was performed according to DIN EN ISO 2719.