EC number: 247-156-8 | CAS number: 25640-78-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Reliability:
- 4 (not assignable)
- Rationale for reliability incl. deficiencies:
- other: Publication meets basic scientific principles, limited documentation
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- The octanol-water partitioning coefficent was determined following the principles of the shake-flask method of OECD TG 107. Test material was shaken with an octanol water mixture, phases were separated by centrifugation and analysed for test substance concentration by GLC.
- GLP compliance:
- no
- Type of method:
- shake-flask method to: flask method
- Partition coefficient type:
- octanol-water
- Analytical method:
- gas chromatography
- Type:
- log Pow
- Partition coefficient:
- 5.2
- Remarks on result:
- other: no temp. specified
- Conclusions:
- The log Kow of isopropylbiphenyl (mixture of isomers) was determined to be 5.20 using the shake flask method and GC analysis of the compound concentrations in the two phases.
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: Acceptable, well-documented study report which meets basic scientific principles, pre-guideline study, but similar to OECD TG 117
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Deviations:
- yes
- Remarks:
- ; retention times not capacity factors used for evaluation, water content of eluent < 25%, only single determinations
- Principles of method if other than guideline:
- Pre-guideline test. The method used was essentially that of Veith GD et al (Water Research 1979, 13, pp. 43-47). This method is similat to OECD TG 117 with some deviations. Reference compounds used are mostly listed in TG 117.
- GLP compliance:
- no
- Remarks:
- pre-GLP study
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Type:
- log Pow
- Partition coefficient:
- 5.33
- Remarks on result:
- other: ambient temp., isomer A
- Type:
- log Pow
- Partition coefficient:
- 5.51
- Remarks on result:
- other: ambient temp., isomer B
- Details on results:
- Log Kow's of the standard compounds were plotted against the log retention time using a linear regression and a second order polynomial fit (Figure 5 of test report, see "Attached background material"). The latter fitted the data better as indicated by the statistics of both regression equations (Table IV of test report). Using the equation from the second order polynomial fit, log Kow values for the test substance were determined. For each of the two isomers of isopropylbiphenyl (IPB), a distinct log Kow value was obtained. Isomers could not be assigned as areas of the HPLC chromatogram were about equal.
- Conclusions:
- Log Kow values of isopropylbiphenyl (mixture of two isomers) were examined in a pre-guideline study using an HPLC method similar to OECD TG 117 with some deviations (retention times not capacity factors used for evaluation, water content of eluent < 25%, only single determinations). The Log Kow values of the two isomers were determined to be 5.33 and 5.51.
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- disregarded due to major methodological deficiencies
- Reliability:
- 3 (not reliable)
- Rationale for reliability incl. deficiencies:
- other: Adequately-documented study report which meets basic scientific principles; but serious deviations from test guidelines
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- The method used resembles OECD TG 107 but shows some restrictions.
Generel procedure:
Test material, dissolved in n-octanol, is shaken with an excess of water for 15 min. Then, water samples are centrifuged and extracted with hexane. After concentration of hexane, the content of test substance is measured by GC analysis. - GLP compliance:
- no
- Remarks:
- pre-GLP study
- Type of method:
- shake-flask method to: flask method
- Remarks:
- pre-guideline study
- Partition coefficient type:
- octanol-water
- Analytical method:
- gas chromatography
- Type:
- log Pow
- Partition coefficient:
- 7
- Remarks on result:
- other: temperature and pH not specified
- Conclusions:
- Compared to current guidelines, the method used has substantial shortcomings. Four parallel experiments were set up. But the hexane extracts seem to have been interspersed. One same experiment was not performed in duplicate. There was no change in conditions between experiments (three different volume ratios, amount of test substance if indicated). Concentration of test substance was analysed only in the aqueous phase but not in the n-octanol phase. The two solvents were not mutually saturated before determination of the partition coefficient. Temperature was not strictly controlled.
- Endpoint:
- partition coefficient
- Type of information:
- calculation (if not (Q)SAR)
- Remarks:
- Migrated phrase: estimated by calculation
- Adequacy of study:
- weight of evidence
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- QSAR calculation
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- Q)SAR calculation with calculation program US EPA EPI Suite v4.11, program component KOWWIN (v1.68); molecular structure is divided into fragments and log Kow is estimated by summing together coefficients for each fragment (AFC method; US EPA 2012. Estimation Programs Interface Suite™ for Microsoft® Windows, v 4.11; United States Environmental Protection Agency, Washington, DC, US).
- Type of method:
- other: calculation
- Partition coefficient type:
- octanol-water
- Type:
- log Pow
- Partition coefficient:
- 5.21
- Remarks on result:
- other: value calculated
Referenceopen allclose all
Substance |
Retention Time |
Log RT |
Log Kow |
IPB isomere A |
11.55 |
1.06 |
5.33 |
IPB isomere B |
13.03 |
1.11 |
5.51 |
Description of key information
Log Kow of (1-methylethyl)-1,1'-biphenyl was determined in a pre-guideline study using a HPLC method similar to OECD TG 117. Similar results were obtained in a study following the principles of OECD TG 107 (Shake Flask Method).
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 5.33
- at the temperature of:
- 20 °C
Additional information
Log Kow of (1-methylethyl)-1,1'-biphenyl was determined in three independent experimental studies (Mendoza/Dow 1981 - HPLC method, Addison 1983 - shake flask method, Ozburn et al 1980 - shake flask method). Results of the first two studies were close together (5.33/5.51 - two different isomers and 5.2, respectively). Log Kow of the Ozburn study was 7. This study was disregarded as experimental conditions were rather deviant from guideline requirements and the result was two orders of magnitude higher than the values of the other two studies. With the estimation program KOCWIN v1.83 within US EPA EPISuite v4.11, a log Kow of 5.21 was calculated that is in good agreement with the experimental values. A log Kow of 5.33 was selected to characterise the substance as this value represents the mean.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.