Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 June 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 1523 (Determination of flash point - Closed cup equilibrium method)
Version / remarks:
2002
Deviations:
yes
Remarks:
carried out according to JIS K 2265 Tag closed-cup test
Principles of method if other than guideline:
Test method: Flash point JIS K 2265 Tag closed cup test
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point:
ca. 28 °C
Atm. press.:
ca. 1 013 mBar

Sample name                                   Test method                       Results

2-methyl butyric acid ethyl   JIS K 2265 Tag closed cup test   28.0°C

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
Flash point has been determined to be 28°C

Description of key information

The flash point of the substance determined by closed cup method is 28°C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
28 °C

Additional information

Sample name                                   Test method                       Results

2-methyl butyric acid ethyl   JIS K 2265 Tag closed[-cup]tester  28.0°C