Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 June 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 1523 (Determination of flash point - Closed cup equilibrium method)
Version / remarks:
2002
Deviations:
yes
Remarks:
carried out according to JIS K 2265 Tag closed-cup test
Principles of method if other than guideline:
Test method: Flash point JIS K 2265 Tag closed cup test
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point:
ca. 28 °C
Atm. press.:
ca. 1 013 mBar

Sample name                                   Test method                       Results

2-methyl butyric acid ethyl   JIS K 2265 Tag closed cup test   28.0°C

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
Flash point has been determined to be 28°C

Description of key information

The flash point of the substance determined by closed cup method is 28°C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
28 °C

Additional information

Sample name                                   Test method                       Results

2-methyl butyric acid ethyl   JIS K 2265 Tag closed[-cup]tester  28.0°C