Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
Name: FAT 41001/H
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: Glowing was observed during heating. No ignition occurred within two minutes.

Safety Pre-Test

A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test

The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

Interpretation of results:
GHS criteria not met
Conclusions:
No ignition was observed throughout the course of the test. The test item FAT 41001/H TE should be considered as not highly flammable.
Executive summary:

FAT 41001/H TE was evaluated for flammability potential in a study conducted according to EU Method A.10. During the preliminary study, the test item was formed into an unbroken strip or powder train about 250 mm long and heated with the flame of a teclu burner. Glowing was observed during heating. The test item showed no signs of ignition. Hence, the test substance FAT 41001/H TE should be considered as not highly flammable.

Description of key information

FAT 41001/H TE was evaluated for flammability potential in a study conducted according to EU Method A.10. During the preliminary study, the test item was formed into an unbroken strip or powder train about 250 mm long and heated with the flame of a teclu burner. Glowing was observed during heating. The test item showed no signs of ignition. Hence, the test substance FAT 41001/H TE should be considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

No ignition was observed throughout the course of the test. The test item FAT 41001/H TE should be considered as not highly flammable.