Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 Feb - 4 March 2008
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: ISO 13320-1 with evaluation according to Fraunhofer
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
other: laser diffraction
Key result
Percentile:
D10
Mean:
99 µm
St. dev.:
0
Remarks on result:
other: Based on 2 measurements
Key result
Percentile:
D50
Mean:
206 µm
St. dev.:
0
Remarks on result:
other: Based on 2 measurements
Key result
Percentile:
D90
Mean:
379 µm
St. dev.:
0
Remarks on result:
other: Based on 2 measurements
Size:
< 10 µm
Distribution:
0 %
Remarks on result:
other: Number was not specified
Conclusions:
The particle size distribution of the substance was determined by laser diffraction analysis. 0% is< 10.00 µm; 10% is < 99 µm; 50% is < 206 µm and 90% is < 379 µm.
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Company data with limited information.
Qualifier:
no guideline followed
Principles of method if other than guideline:
Sieve analysis.
GLP compliance:
no
Type of method:
other: not specified
Percentile:
D50
Remarks on result:
not measured/tested
Size:
> 2.36 mm
Distribution:
12 %
Remarks on result:
other: number not specified
Size:
> 1.7 mm
Distribution:
66 %
Remarks on result:
other: number not specified
Size:
> 1.18 mm
Distribution:
97 %
Remarks on result:
other: number not specified
Size:
> 0.85 mm
Distribution:
99 %
Remarks on result:
other: number not specified
Conclusions:
Sieve analysis showed that 99% of sodium nitrate (prilled form) is > 0.85 mm.

Description of key information

Laser diffraction analysis result for sodium nitrate (crystalline powder): 0% is < 10.00 µm, 10% is < 99 µm, 50%  is < 206 µm and  90% is < 379 µm.  

Sieve analysis result for prilled sodium nitrate:  99% is > 0.85 mm.

Additional information