Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 454-800-3 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Vapour pressure
Administrative data
Link to relevant study record(s)
- Endpoint:
- vapour pressure
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.4 (Vapour Pressure)
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 104 (Vapour Pressure Curve)
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- other: dynamic method + vapor pressure balance
- Temp.:
- 20 °C
- Vapour pressure:
- 0.17 Pa
- Temp.:
- 25 °C
- Vapour pressure:
- 0.4 Pa
- Temp.:
- 50 °C
- Vapour pressure:
- 11 Pa
- Conclusions:
- The vapour pressure of 2-chloro-5-chloromethylpyridine at 20°C was determined as 0.17 Pa and at 25°C as 0.4 Pa.
- Executive summary:
A study was conducted to assess the vapour pressure of 2 -chloro-5-chloromethylpyridine according to EU test method A.4 which is equal to OECD test guideline 104. The effusion method (vapour pressure balance) and the dynamic method were used for the determination.
Vapour Pressure Balance (Effusion Method)
The apparatus consists of a high vacuum chamber. The test item is filled into a furnace in the chamber from which the sample evaporates. The temperature of the ceil with the test item is controlled by a surrounding heater. The vapour forms a molecular jet of defined geometry limited by an orifice. The vapour jet is condensed on a plate cooled down below - 100 °C by a surrounding copper baffle which is in contact with liquid nitrogen. The plate forms one end of an ultra micro balance.
The pressure of the test item is calculated from the weight increase during an elapsed time period.
The vapour pressure was at first measured in the temperature range of 21 °C to 31 °C by Effusion Method (Vapour Pressure Balance). The course of the vapour pressure show a broad scatter. From these data points it is concluded, that the measured vapour pressure is mainly influenced by volatile by-products, which are available in the test item only in limited quantities.
An additional measurement with the dynamic method was performed.
Vapour Pressure (Dynamic Method)
The vapour pressure is measured by determining the boiling point of the test item at various specified pressures between roughly 10 and 1000 hPa.
Before filling the test apparatus the whole equipment was flooded with nitrogen to minimize the presence of oxygen. After filling the apparatus with the test item the lowest desired pressure is set and the heating system is switched on. Equilibrium is reached when a constant boiling temperature is achieved at a given pressure. After recording this point the pressure is increased step by step and up to the boiling point.
The Antoine constants from the regression of all data from both methods (vapour pressure balance and dynamic method) were used to calculate the vapour pressure for 20, 25 and 50 °C, which were 0.17, 0.4 and 11 Pa respectively.
Reference
The vapour pressure was at first measured in the temperature range of 21 °C to 31 °C by Effusion Method (Vapour Pressure Balance). The course of the vapour pressure show a broad scatter. From these data points it is concluded, that the measured vapour pressure is mainly influenced by volatile by-products, which are available in the test item only in limited quantities.
An additional measurement with the dynamic method was performed.
The Antoine constants from the regression of all data from both methods (vapour pressure balance and dynamic method) were used to calculate the vapour pressure for 20, 25 and 50 °C.
Description of key information
A study was conducted to assess the vapour pressure of 2 -chloro-5-chloromethylpyridine according to EU test method A.4 which is equal to OECD test guideline 104. The effusion method (vapour pressure balance) and the dynamic method were used for the determination.
Vapour Pressure Balance (Effusion Method)
The apparatus consists of a high vacuum chamber. The test item is filled into a furnace in the chamber from which the sample evaporates. The temperature of the ceil with the test item is controlled by a surrounding heater. The vapour forms a molecular jet of defined geometry limited by an orifice. The vapour jet is condensed on a plate cooled down below - 100 °C by a surrounding copper baffle which is in contact with liquid nitrogen. The plate forms one end of an ultra micro balance.
The pressure of the test item is calculated from the weight increase during an elapsed time period.
The vapour pressure was at first measured in the temperature range of 21 °C to 31 °C by Effusion Method (Vapour Pressure Balance). The course of the vapour pressure show a broad scatter. From these data points it is concluded, that the measured vapour pressure is mainly influenced by volatile by-products, which are available in the test item only in limited quantities.
An additional measurement with the dynamic method was performed.
Vapour Pressure (Dynamic Method)
The vapour pressure is measured by determining the boiling point of the test item at various specified pressures between roughly 10 and 1000 hPa.
Before filling the test apparatus the whole equipment was flooded with nitrogen to minimize the presence of oxygen. After filling the apparatus with the test item the lowest desired pressure is set and the heating system is switched on. Equilibrium is reached when a constant boiling temperature is achieved at a given pressure. After recording this point the pressure is increased step by step and up to the boiling point.
The Antoine constants from the regression of all data from both methods (vapour pressure balance and dynamic method) were used to calculate the vapour pressure for 20, 25 and 50 °C, which were 0.17, 0.4 and 11 Pa respectively.
Key value for chemical safety assessment
- Vapour pressure:
- 0.17 Pa
- at the temperature of:
- 20 °C
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.