EC number: 233-466-0 | CAS number: 10191-41-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
Remove contaminated clothing.
If inhaled: Keep patient calm, remove to fresh air.
On skin contact: Wash thoroughly with soap and water.
On contact with eyes: Wash affected eyes for at least 15 minutes under running water with eyelids held open.
On ingestion: Rinse mouth and then drink plenty of water.
Symptoms: No significant reaction of the human body to the product known.
Treatment: Symptomatic treatment (decontamination, vital functions).
Fire-fighting measures
Suitable extinguishing media: Dry powder, carbon dioxide, water spray, alcohol-resistant foam
Unsuitable extinguishing media for safety reasons: water jet, Not alcohol resistant foam
Special hazards arising from the substance or mixture: carbon oxides, harmful vapours can be released in case of fire.
Advice for fire-fighters: Wear a self-contained breathing apparatus.
Further information: Can form explosive gas/air mixtures. Cool endangered containers with water-spray. Dispose of fire debris and contaminated extinguishing water in accordance with official regulations.
Accidental release measures
Personal precautions, protective equipment and emergency procedures: No special precautions necessary, use personal protective clothing.
Environmental precautions: Do not discharge into drains/surface waters/groundwater.
Methods and material for containment and cleaning up: For small amounts: Pick up with suitable absorbent material. For large amounts: Dike spillage. Pump off product. For residues: Contain with absorbent material (e.g. sand, silica gel, acid binder, general purpose binder, sawdust). Sweep/shovel up.
Dispose of absorbed material in accordance with regulations.
Handling and storage
Precautions for safe handling: No special measures necessary provided product is used correctly. Handle in accordance with good industrial hygiene and safety practices
Protection against fire and explosion: Take precautionary measures against static discharges. Avoid all sources of ignition: heat, sparks, open flame.
Conditions for safe storage, including any incompatibilities: Suitable materials for containers: use only use approved steel and plastic containers (stainless steel, polyethylene, high density polyethylene (HDPE), glass)
Further information on storage conditions: Containers should be stored tightly sealed in a dry place. Keep under inert gas. Protect from of light, air and heat.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Personal protective equipment:
Respiratory protection: Not applicable with adequate ventilation
Hand protection: No special protection needed under normal conditions of use. Wear suitable gloves.
Eye protection: Safety glasses with side-shields (frame goggles) (e.g. EN 166)
Body protection: Body protection must be chosen based on level of activity and exposure.
General safety and hygiene measures: Handle in accordance with good industrial hygiene and safety practice.
Stability and reactivity
Reactivity: No hazardous reactions if stored and handled as prescribed/indicated.
Corrosion to metals: Corrosive effects to metal are not anticipated.
Formation of flammable gases: Forms no flammable gases in the presence of water.
Chemical stability: The product is stable if stored and handled as prescribed/indicated.
Possibility of hazardous reactions: None if used for intended purpose.
Disposal considerations
Observe national and local legal requirements.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.