Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-like

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
no
Type of method:
other: DSC

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Melting / freezing pt.:
>= 219 °C
Atm. press.:
ca. 1 013 hPa
Decomposition:
yes
Decomp. temp.:
>= 219 °C
Sublimation:
no

Applicant's summary and conclusion

Conclusions:
The test item shows no melting of crystalline subcomponents (in the 1st to 3rd heating run) up to 219°c (at 219°c probably the test item starts to decompose) according to the definition in the OECD Guideline 102 (mean value from repeat determinations).