Registration Dossier

Administrative data

Endpoint:
dissociation constant
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-like

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 112 (Dissociation Constants in Water)
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Dissociating properties:
no

Applicant's summary and conclusion

Conclusions:
Test item solutions with concentrations of approx. 5 g/L only generates conductivity values below 20 µS/cm . Due to this low conductivity only minor parts of the test item dissociates into ions.
The calculation of the dissociation constant was not possible.